{"id":3784,"date":"2020-12-14T20:10:15","date_gmt":"2020-12-14T20:10:15","guid":{"rendered":"https:\/\/www.te-italy.com\/forni-secondo-normativa-ams-2750-f\/"},"modified":"2020-12-14T21:15:12","modified_gmt":"2020-12-14T21:15:12","slug":"furnaces-according-ams2750f-standard","status":"publish","type":"page","link":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/","title":{"rendered":"Furnaces according to AMS 2750 F standard"},"content":{"rendered":"<h1 class=\"page-title\">Reference Standards<\/h1>\n<h4>Furnaces according to the 2750 F, NADCAP, CQI-9 standard<\/h4>\n<p>AMS 2750 F (Before 29-06-2020 AMS 2750 E) &#8211; Aerospace Material Speci\ufb01cations- is a standard for the processing of high quality materials in industry. <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"5\">These standards describe the requirements related to heat treatment. The AMS 2750 F standard and derived standards such as AMS 2770 for the heat treatment of aluminum are today the reference standard for the aeronautical and space industry. With the introduction of the CQI-9, the automotive industry is now committed to subjecting heat treatment processes to stricter rules. These standards describe in detail the requirements relating to thermal process plants:<\/span><\/p>\n<p><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"5\">\u2022 Uniformity of the temperature in the useful compartment (TUS)<\/span><\/p>\n<p><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"5\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"1\">\u2022 Instrumentation (requirements for measuring and regulating devices) <\/span><\/span><\/p>\n<p><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"5\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"1\">\u2022 Calibration of the measuring line (IT) from the controller via the measuring cable to the thermocouple<\/span><\/span><\/p>\n<p><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"5\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"1\">\u2022 System accuracy check (SAT) <\/span><\/span><\/p>\n<p><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"5\"><span class=\"JLqJ4b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"1\">\u2022 Documentation of the verification cycles<\/span><\/span><\/p>\n<p>Compliance with the regulations is necessary in order to guarantee compliance with the quality standard required for the components to be made even in the mass production phase. <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"1\">For this reason, extensive and repeated checks are required, as well as instrumentation checks including related documentation.<\/span><\/p>\n<h4>AMS 2750 F requirements for furnace class and instrumentation<\/h4>\n<p>Depending on the quality requirements for the component to be subjected to heat treatment, the customer provides information on the type of instrumentation and the temperature uniformity class. <span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"it\" data-phrase-index=\"1\">The type of instrumentation describes the necessary composition of the control system used, of the recording instruments and of the thermocouples. The uniformity of the oven temperature and the quality of the instrumentation used depends on the required oven class. The higher the requirements regarding the furnace class, the more precise the instrumentation must be made.<\/span><\/p>\n<p>Below is a simplified illustration that schematizes the equipment of the ovens that comply with the AMS 2750 F standard<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3799\" src=\"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F.jpg\" alt=\"AMS2705F Schema forno\" width=\"900\" height=\"663\" srcset=\"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F.jpg 900w, https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F-300x221.jpg 300w, https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F-768x566.jpg 768w, https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F-254x187.jpg 254w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3796\" src=\"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Tabella_AMS2750F.jpg\" alt=\"AMS2750F instrumentation\" width=\"1050\" height=\"231\" srcset=\"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Tabella_AMS2750F.jpg 1050w, https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Tabella_AMS2750F-300x66.jpg 300w, https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Tabella_AMS2750F-1024x225.jpg 1024w, https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Tabella_AMS2750F-768x169.jpg 768w, https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Tabella_AMS2750F-280x62.jpg 280w\" sizes=\"auto, (max-width: 1050px) 100vw, 1050px\" \/><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Reference Standards Furnaces according to the 2750 F, NADCAP, CQI-9 standard AMS 2750 F (Before 29-06-2020 AMS 2750 E) &#8211; Aerospace Material Speci\ufb01cations- is a standard for the processing of high quality materials in industry. These standards describe the requirements related to heat treatment. The AMS 2750 F standard and derived standards such as AMS<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_exactmetrics_skip_tracking":false,"footnotes":""},"class_list":["post-3784","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Furnaces according to AMS 2750 F standard - Thermal Enginnering Srl<\/title>\n<meta name=\"description\" content=\"Industrial furnaces, both laboratory and industrial, with Uniformity according to AMS2750F\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Furnaces according to AMS 2750 F standard - Thermal Enginnering Srl\" \/>\n<meta property=\"og:description\" content=\"Industrial furnaces, both laboratory and industrial, with Uniformity according to AMS2750F\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/\" \/>\n<meta property=\"og:site_name\" content=\"Thermal Enginnering Srl\" \/>\n<meta property=\"article:modified_time\" content=\"2020-12-14T21:15:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/\",\"url\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/\",\"name\":\"Furnaces according to AMS 2750 F standard - Thermal Enginnering Srl\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.te-italy.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Schema_AMS2750F.jpg\",\"datePublished\":\"2020-12-14T20:10:15+00:00\",\"dateModified\":\"2020-12-14T21:15:12+00:00\",\"description\":\"Industrial furnaces, both laboratory and industrial, with Uniformity according to AMS2750F\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.te-italy.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Schema_AMS2750F.jpg\",\"contentUrl\":\"https:\\\/\\\/www.te-italy.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Schema_AMS2750F.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/furnaces-according-ams2750f-standard\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.te-italy.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Furnaces according to AMS 2750 F standard\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/#website\",\"url\":\"https:\\\/\\\/www.te-italy.com\\\/\",\"name\":\"Thermal Enginnering Srl\",\"description\":\"ATMOSPHERE HEAT TREATMENT FURNACES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.te-italy.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/#organization\",\"name\":\"Thermal Engineering Srl\",\"url\":\"https:\\\/\\\/www.te-italy.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.te-italy.com\\\/wp-content\\\/uploads\\\/2018\\\/05\\\/logo-thermal-engineering.png\",\"contentUrl\":\"https:\\\/\\\/www.te-italy.com\\\/wp-content\\\/uploads\\\/2018\\\/05\\\/logo-thermal-engineering.png\",\"width\":244,\"height\":85,\"caption\":\"Thermal Engineering Srl\"},\"image\":{\"@id\":\"https:\\\/\\\/www.te-italy.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Furnaces according to AMS 2750 F standard - Thermal Enginnering Srl","description":"Industrial furnaces, both laboratory and industrial, with Uniformity according to AMS2750F","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/","og_locale":"en_US","og_type":"article","og_title":"Furnaces according to AMS 2750 F standard - Thermal Enginnering Srl","og_description":"Industrial furnaces, both laboratory and industrial, with Uniformity according to AMS2750F","og_url":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/","og_site_name":"Thermal Enginnering Srl","article_modified_time":"2020-12-14T21:15:12+00:00","og_image":[{"url":"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/","url":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/","name":"Furnaces according to AMS 2750 F standard - Thermal Enginnering Srl","isPartOf":{"@id":"https:\/\/www.te-italy.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/#primaryimage"},"image":{"@id":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/#primaryimage"},"thumbnailUrl":"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F.jpg","datePublished":"2020-12-14T20:10:15+00:00","dateModified":"2020-12-14T21:15:12+00:00","description":"Industrial furnaces, both laboratory and industrial, with Uniformity according to AMS2750F","breadcrumb":{"@id":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/#primaryimage","url":"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F.jpg","contentUrl":"https:\/\/www.te-italy.com\/wp-content\/uploads\/2020\/12\/Schema_AMS2750F.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.te-italy.com\/en\/furnaces-according-ams2750f-standard\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.te-italy.com\/en\/"},{"@type":"ListItem","position":2,"name":"Furnaces according to AMS 2750 F standard"}]},{"@type":"WebSite","@id":"https:\/\/www.te-italy.com\/#website","url":"https:\/\/www.te-italy.com\/","name":"Thermal Enginnering Srl","description":"ATMOSPHERE HEAT TREATMENT FURNACES","publisher":{"@id":"https:\/\/www.te-italy.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.te-italy.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.te-italy.com\/#organization","name":"Thermal Engineering Srl","url":"https:\/\/www.te-italy.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.te-italy.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.te-italy.com\/wp-content\/uploads\/2018\/05\/logo-thermal-engineering.png","contentUrl":"https:\/\/www.te-italy.com\/wp-content\/uploads\/2018\/05\/logo-thermal-engineering.png","width":244,"height":85,"caption":"Thermal Engineering Srl"},"image":{"@id":"https:\/\/www.te-italy.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/pages\/3784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/comments?post=3784"}],"version-history":[{"count":5,"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/pages\/3784\/revisions"}],"predecessor-version":[{"id":3804,"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/pages\/3784\/revisions\/3804"}],"wp:attachment":[{"href":"https:\/\/www.te-italy.com\/en\/wp-json\/wp\/v2\/media?parent=3784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}